Telemetry
⦾ Why does the telemetry service fail on a compute node and the Telemetry database remains empty after executing omnia.yml in a cross-OS setup where the OIM is running Ubuntu 22.04 and the compute nodes are on Ubuntu 20.04?
Potential Cause: This issue is encountered when there is a mismatch of libc version between the OIM (running on Ubuntu 22.04) and the compute node (running on Ubuntu 20.04).
Resolution: To ensure proper functioning of the telemetry service, ensure that the same libc version is present on the OIM and the compute nodes.
⦾ Why are there no telemetry metrics available for the AMD accelerators in Omnia telemetry?
Potential Cause: This issue is encountered due to a change in the API response format introduced in the latest AMD ROCm 6.2.2 driver.
If you have any feedback about Omnia documentation, please reach out at omnia.readme@dell.com.