Network ======== ⦾ **Why does the** ``TASK [infiniband_switch_config : Authentication failure response]`` **fail with the message:** ``Status code was -1 and not [302]: Request failed: `` **on Infiniband Switches when executing** ``infiniband_switch_config.yml`` **playbook?** **Potential Cause**: To configure a new Infiniband Switch, HTTP and JSON gateway must be enabled. To verify that they are enabled, run: * Check if HTTP is enabled: ``show web`` * Check if JSON Gateway is enabled: ``show json-gw`` **Resolution**: To correct the issue, run: * Enable the HTTP gateway: ``web http enable`` * Enable the JSON gateway: ``json-gw enable`` ⦾ **During consecutive runs of the** ``server_spec_update.yml`` **playbook, the additional NICs may not be configured according to the inputs provided in the** ``input/server_spec.yml`` **file, or any unexpected behavior may occur.** **Potential Cause**: Omnia does not support modifying the category definitions (for example, ``nic_name``, ``nicnetwork``, or ``nictype``) in ``input/server_spec.yml`` or changing the category details in the inventory file provided, during consecutive runs of the ``server_spec_update.yml`` playbook. **Resolution**: Re-provision the nodes.